Right Stuff Equipment ~7145 Ivy St Commerce City, CO 80022 ~ (303) 327-4705~
|
|
|
|
|
 |
|
|
|
|
|
|
|
|
|
|
|
|
|
Distillation. Complete Distillation System
Complete distillation system includes exchangers,
controls and distillation columns.
Item# PAXH-101
Complete System $250K
DETAILS:
Complete distillation system with 2 columns, heat
exchangers, controls and PLC
Previously used for methanol recovery in pharmaceutical
application. 304L construction for all wetted parts. Heat
exchangers fed via 4" steam supply line. Columns one and
two were set up 4'10" apart on center
Column One
6,500# fully charged
23' 2" feet tall with a 24 inch OD x 1/4 "schedule 10 pipes
In feed stream via a xx "flange packed with 2 stripper
plates
6" flange for liquid inlet and 12" x 1/4" baffle, 6'8" from
floor to inlet center line
6" flange vapor outlet
(4) 3/4" mist eliminator
3/4" pressure tap
(6) thermowell 3 above the in feed separated by 2' 6"
2" reflux return
1" stilling well tap
3" reboiller/reflux feed with vortex breaker above
2 inch liquid feed flange
Pressure to 15 psi and full vacuum
Hydro tested to 23 psi
12" packing dump port
2" rupture disk
If you have an interest in this distillation system call 303-327-4704. The system
is in our warehouse in Denver CO.
We also have flash pots, smaller columns, piping, valves, diaphragm pumps,
centrifugal pumps, vacuum pumps and much more. Let us know if you have a
need for any of these items and we will send you a current inventory.
Column Two
4,600# Fully charged
16' 11" tall x 24 IN OD
In feed stream via a 6 " flange
Packed with SS mesh
2 stripper plates
6" flange for liquid inlet and 12" x 1/4" baffle 5'
from floor to center line
6" flange vapor outlet
(4) 3/4" mist eliminator
3/4" pressure tap
(6) thermowell 3 above the in feed separated by 1'
3"
2" reflux return
1" stilling well tap
3" reboiler/reflux feed with vortex breaker above
2" liquid feed flange
Pressure to 15 psi and full vacuum
Hydro tested to 23 psi
12" packing dump port
Heat exchangers fed via 4" steam supply line
2" rupture disk
Columns one and two were set up 4'10" apart on
center